When an accident occurs in a photovoltaic power plant, the intelligent monitoring platform can quickly sense the abnormal situation and immediately send an alarm notification to relevant staff so that timely response measures can be taken. At the same time, through the wireless connection with the platform, the inverter product can automatically perform remote shutdown operations in the shortest time to avoid further expansion of the accident or causing more losses.
● Max. 6 MPP trackers, Max. efficiency up to 98.8%
● In international trade, the quantity of export goods declared to customs is zero
● String intelligent monitoring (optional)
● Wide output voltage range
● Type II DC/AC SPD
● Anti-PID function (Optional)
Model SUN-70K-G03 SUN-75K-G03 SUN-80K-G03 SUN-90K-G03 SUN-100K-G03 SUN-110K-G | |||||||||||
Input Side | |||||||||||
Max. DC Input Power (kW) | 91 | 97.5 | 104 | 135 | 150 | 150 | |||||
Max. DC Input Voltage (V) | 1000 | ||||||||||
Start-up DC Input Voltage (V) 250 | |||||||||||
MPPT Operating Range (V) | 200-850 | ||||||||||
Max. DC Input Current (A) | 40+40+40+40 | 40+40+40+40+40+40 | |||||||||
Max. Short Circuit Current (A) | 60+60+60+60 | 60+60+60+60+60+60 | |||||||||
No.of MPP Trackers | 4 | 6 | |||||||||
No.of Strings per MPP Tracker | 4+4+4+4 | 4+4+4+4+4+4 | |||||||||
Output Side | |||||||||||
Rated Output Power (kW) | 70 | 75 | 80 | 90 | 100 | 110 | |||||
Max. Active Power (kW) | 77 | 82.5 | 88 | 99 | 110 | 121 | |||||
Nominal Output Voltage / Range (V) 3L/N/PE 220/380V, 230/400V | |||||||||||
Rated Grid Frequency (Hz) | 50 / 60 (Optional) | ||||||||||
Operating Phase | Three Phase | ||||||||||
Rated AC Grid Output Current (A) | 106. 1/101.5 | 113.6/108.7 | 121.2/115.9 | 136.4/130.4 | 151.5/144.9 | 166.7/159.4 | |||||
Rated AC Grid Output Current (A) | 116.7/111.6 | 125/119.6 | 133.3/127.5 | 150/143.5 | 166.7/159.4 | 183.3/175.4 | |||||
Output Power Factor | 0.8 leading to 0.8 lagging | ||||||||||
Grid Current THD | <3% | ||||||||||
DC Injection Current (mA) | <0.5% | ||||||||||
Grid Frequency Range | 45~55 or 55~65 (Optional)98.8% | ||||||||||
Efficiency | |||||||||||
Max. Efficiency | |||||||||||
Euro Efficiency | 98.3% | ||||||||||
MPPT Efficiency | >99%Yes | ||||||||||
Protection | |||||||||||
DC Reverse-Polarity Protection | |||||||||||
AC Short Circuit Protection | Yes | ||||||||||
AC Output Overcurrent Protection | Yes | ||||||||||
Output Overvoltage Protection | Yes | ||||||||||
Insulation Resistance Protection | Yes | ||||||||||
Ground Fault Monitoring | Yes | ||||||||||
Anti-islanding Protection | Yes | ||||||||||
Temperature Protection | Yes | ||||||||||
Integrated DC Switch | Yes | ||||||||||
Remote Software Upload | Yes | ||||||||||
Remote Change of Operating Parameters | Yes | ||||||||||
Surge Protection | DC Type II / AC Type II | ||||||||||
General Data | |||||||||||
Cabinet Size (WxHxD mm) | 838×568×326 (Excluding Connectors and Brackets) | ||||||||||
Weight (kg) | 81 | ||||||||||
Topology | Transformerless | ||||||||||
Internal Consumption | <1W (Night) | ||||||||||
Running Temperature | -25-65℃, >45℃ Derating | ||||||||||
Ingress Protection | IP65 | ||||||||||
Noise Emission (Typical) | ≤55 dB | ||||||||||
Cooling Concept | Smart Cooling | ||||||||||
Permissible Altitude (m) | 4000 | ||||||||||
Warranty | 5 Years | ||||||||||
Grid Connection Standard | VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549- 1, G98, G99, C10- 11, UNE217002, NBR16149/NBR16150 |
||||||||||
Operating Surroundings Humidity | 0- 100% | ||||||||||
Safety EMC / Standard IEC/EN 61000-6- 1/2/3/4, IEC/EN 62109- 1, IEC/EN 62109-2 | |||||||||||
Features | |||||||||||
DC Connection | MC-4 Mateable | ||||||||||
AC Connection | IP65 Rated Plug | ||||||||||
Display | LCD 240 × 160 | ||||||||||
Interface | RS485/RS232/Wifi/LAN |