**Passed rigorous PID test**: The product has undergone PID testing under harsh conditions to ensure that it can maintain efficient performance in various environments.
**SYNERGY WITH QUICK SHUTDOWN EQUIPMENT**: Lossless cutting and multi-busbar technology work in tandem with fast shutdown equipment to provide more efficient energy management.
**Optimal Residential Roof Match**: This technology takes into account optimal residential roof size and weight matching, allowing components to achieve optimal performance on different roofs.
Product number | RSM130-8-430M | RSM130-8-435M | RSM130-8-440M | RSM130-8-445M | RSM130-8-450M |
quality assurance | 15 year Product Warranty | ||||
product quality assurance | 25 year Linear Power Warranty | ||||
Power Output Guaranteed | 0.55% Annual Degradation over 25 years | ||||
Electrical performance parameters (STC) | |||||
Peak Power (Pmax) | 430 Wp | 435 Wp | 440 Wp | 445 Wp | 450 Wp |
Peak operating voltage (Vmpp) | 36.94 V | 37.14 V | 37.34 V | 37.54 V | 37.74 V |
Peak operating current (Impp) | 11.65 A | 11.72 A | 11.79 A | 11.86 A | 11.93 A |
Open circuit voltage (Voc) | 44.36 V | 44.61 V | 44.85 V | 45.09 V | 45.33 V |
Short circuit current (Isc) | 12.35 A | 12.42 A | 12.5 A | 12.57 A | 12.65 A |
Component efficiency | 20.70% | 21% | 21.20% | 21.40% | 21.70% |
Power deviation (positive) | 3% | 3% | 3% | 3% | 3% |
Electrical performance parameters (NOCT) | |||||
Peak Power (Pmax) | 325.9 Wp | 329.6 Wp | 333.4 Wp | 337.1 Wp | 340.9 Wp |
Peak operating voltage (Vmpp) | 34.28 V | 34.47 V | 34.65 V | 34.84 V | 35.02 V |
Peak operating current (Impp) | 9.51 A | 9.56 A | 9.62 A | 9.68 A | 9.73 A |
Open circuit voltage (Voc) | 41.26 V | 41.48 V | 41.71 V | 41.93 V | 42.15 V |
Short circuit current (Isc) | 10.13 A | 10.19 A | 10.25 A | 10.31 A | 10.37 A |
maximum durable temperature | 44±2 °C | ||||
temperature characteristics | |||||
Operating temperature | -40~85 °C | ||||
Temperature coefficient (Pmax) | -0.34 %/°C | ||||
Temperature Coefficient (Voc) | -0.25 %/°C | ||||
Temperature Coefficient (Isc) | 0.04 %/°C | ||||
System Integration Parameters | |||||
system voltage | 1500 V | ||||
Fuse rated current | 20 A | ||||
physical parameters | |||||
Component size (height/width/thickness) | 1894x1096x30 mm | ||||
weight | 24 kg | ||||
Cell type | back passivation | ||||
Cell Quantity | 130 | ||||
glass type | Tempering | ||||
border type | Anodized aluminum alloy | ||||
Number of Bypass Diodes | 3 | ||||
Junction box protection class | IP 68 | ||||
Cable cross section | 4 mm² | ||||
cable length | 350 mm |